Series HLF

HLF series with axial fan and oil drain pan
HLF series with axial fan and oil drain pan
HLF burner hood
HLF burner hood

S+H / Nolting - warm air heaters for mobile deployment. Quick available heat at the right place by directed air control. 

  • Heating and ventilation of tents
    for exhibitions or events and workshops
  • Heating of protective quarters
  • Heating of construction sites
  • Thawing and de-icing of construction materials
  • Agricultural applications
  • Drying of grain
  • Horticulture applications

S+H / Nolting  mobile warm air heaters offer an approved technology, meet highest requirements of quality and guarantee a high secure supply of the most different applications.

Standard equipment is: 

  • Oil burner
  • One run filter with quick extractor fan
  • Heat exchanger made of steel,
    extremly heat resistant
  • Double layer outer casing to insulate
    against heat losses
  • Strong chassis for difficult grounds
  • RAL colour 7035 + 7016

All conventional oil and gas burners can be used.

Illustrations partly with configuration possibilities

Possibilities of configuration:

  • Gas burner
  • Oil preheating
  • burner hood with oil drip tray
  • Wet room thermostat including
    cable of 10 m plus connceting plug
  • Exhaust system
  • Warm air hoses
  • Blow out adapter
  • Front deflection pulley
  • Varnish possible in any RAL colour wanted
DIN geprüft CE TÜV Cert

Further information:

Product sheet HLF series

Technical Data:

Type of unit
HLF 30
HLF 50
HLF 75
HLF 120
HLF 150
Model     Axial Fan
Nominal heat loading capacity   kW  28 50 75 120 158
Rated heat output   kW  23 45 69 110 150
Air capacity   m³/h  2,400 4,500 5,800 8,500 11,000
Discharge pressure   mbar  0.5 0.5 0.5 0.5 1.0
Motor power   kW  0.13 0.48 0.64 1.15 1.85
Electric supply   V/Hz  230 / 50
Length   mm  1,255 1,510 1,610 1,820 1,960
Width   mm  560 640 720 785 785
Height   mm  910 1,015 1,015 1,185 1,400
Air outlet   ø A  300 400 450 500 600
Flue gas   ø R  150 150 150 200 200
Weight without burner   kg  110 140 170 260 350

Version: 2022-08